Directly Driving Motor, Low Noise, Low Vibration, High Efficiency Synchronous Motor 6000rpm

Product Details
Customization: Available
Application: Industrial, Power Tools, Fans, Pumps, Compressors
Operating Speed: High Speed
Still deciding? Get samples of US$ 1000/Piece
Request Sample
Manufacturer/Factory & Trading Company

360° Virtual Tour

Diamond Member Since 2018

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Number of Employees
51
Year of Establishment
2016-10-09
  • Directly Driving Motor, Low Noise, Low Vibration, High Efficiency Synchronous Motor 6000rpm
  • Directly Driving Motor, Low Noise, Low Vibration, High Efficiency Synchronous Motor 6000rpm
  • Directly Driving Motor, Low Noise, Low Vibration, High Efficiency Synchronous Motor 6000rpm
  • Directly Driving Motor, Low Noise, Low Vibration, High Efficiency Synchronous Motor 6000rpm
Find Similar Products

Basic Info.

Model NO.
SRPM210L8F18.5
Operation Mode
Electric Motor
Magnetic Structure
Permanent Magnet
Function
Driving
Structure
Rotating Pole Type (Armature Fixed)
Number of Poles
8
Ventilation
Closed
Certification
ISO9001, CE, RoHS
Brand
Mc-Motor
Usage
Fans, Pumps, Compressors
Net Weight
37kg
Efficiency
94%
Transport Package
1PC/ Carton ( Wood /Paper Box Optional)
Specification
TBD (based on real motor dimension)
Trademark
mc motor
Origin
China
HS Code
8501520000
Production Capacity
100000 Sets

Product Description

High efficiency Air cooling 380V AC 18.5KW 6000RPM Brushless PM Electric Motor

Product Feature
1.Suitable for the 6000rpm rated speed
2.High power & high torque
3.High efficiency
4.Small size
5.Low noise low vibration
6.Patented cooling structure
7.Easy maintenance and long life time
8.Durable, reliable


Specifications
Model type: SRPM210L8F18.5
Voltage: 380V AC
Rated Power: 6KW
Rated Torque :33.4N.m
Rated speed: 6000rpm
Isolation: H/F
Water/dust Proof: IP54(IP67 option)

Cooling Method: Air
Installation Method: B35



Application
High-speed Compressors,Fans,Pumps
Directly Driving Motor, Low Noise, Low Vibration, High Efficiency Synchronous Motor 6000rpm
Directly Driving Motor, Low Noise, Low Vibration, High Efficiency Synchronous Motor 6000rpm
Directly Driving Motor, Low Noise, Low Vibration, High Efficiency Synchronous Motor 6000rpm
Directly Driving Motor, Low Noise, Low Vibration, High Efficiency Synchronous Motor 6000rpm
Other motors you will be interested in
Motor type Voltage
(V AC)
Rated power
(kW)
Rated torque (N.m) Rated speed
(rpm)
Efficiency
(%)
Service Factor Insulation Ingress protection Pole Number Weight
(kg)
Cooling Method Position Signal Installation Method
SRPM151M8XW11 380 11 11 9600 96 S1 H/F IP67 8 10 Oil circulation Resolver B35
SRPM205M8XO45 380 45 36 12000 96.3 S1 H/F IP67 8 35 Oil circulation Resolver B35
SRPM205M8XO55 380 55 43.8 12000 96.3 S1 H/F IP67 8 38 Oil circulation Resolver B35
SRPM205M8XO75 380 75 59.7 12000 96.5 S1 H/F IP67 8 43 Oil circulation Resolver B35
SRPM205M8XO90 380 90 71.6 12000 96.5 S1 H/F IP67 8 47 Oil circulation Resolver B35
SRPM205M8XO110 380 110 87.6 12000 96.5 S1 H/F IP67 8 75 Oil circulation Resolver B35
SRPM205M8XO132 380 132 105 12000 96.5 S1 H/F IP67 8 80 Oil circulation Resolver B35
SRPM205M8XO160 380 160 127.3 12000 96.5 S1 H/F IP67 8 87 Oil circulation Resolver B35
SRPM205M8XO185 380 185 147.2 12000 96.5 S1 H/F IP67 8 95 Oil circulation Resolver B35
FAQ
1. Can performanent magnet synchronous motor be used as generator? 

Yes. Permanent magnet synchronous motor  can work as a generator because of its special working theory. If it runs CW as a motor, then runs CCW as a generator. But please kindly note, if when you want to work it as a generator, you need to change a suitable motor controller with AFE function
 
2. Why can not directly use three phase ac supply voltage to start permanent magnet synchronous motor? 
Becuase rotor is with big innertia, and magetic files spins so fast that static rotor has no way to spin with magetic filed. 
 
3. Any special technical request on this motor's VFD driver? And Do you have such driver? 
Permanent magnet synchronous motor's driver should be vector control VFD with special inner software, such as Siemens 6SE70 series, Yakawa CR5 series, ABB ACS800 series, Mitsubishi A740 series, B&R P84 and P74 series, etc.. Yes, our MH300 series VFD matches with this motor. 
 
4. Is there any protective measures to defend permanent magnet rotor from failure? 
Yes, each permanent magnet rotor passes corrossion resistance, consistency, high temperature demagnetization test, linear demagnetization test, etc. Its demagnetization index is within 2%. But if working environment is serious oxiditive corrosion, kindly advise for higher protection level. 
 
5. Where is this permanent magnet synchronous motor normally used to? 
This permanent magnet synchronous motor is normally used to variable frequency speed situation.

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier