• 15kw 24000rpm High Speed Permanent Magnetic Synchronous Motor for Turbo Blower
  • 15kw 24000rpm High Speed Permanent Magnetic Synchronous Motor for Turbo Blower
  • 15kw 24000rpm High Speed Permanent Magnetic Synchronous Motor for Turbo Blower
  • 15kw 24000rpm High Speed Permanent Magnetic Synchronous Motor for Turbo Blower
  • 15kw 24000rpm High Speed Permanent Magnetic Synchronous Motor for Turbo Blower
  • 15kw 24000rpm High Speed Permanent Magnetic Synchronous Motor for Turbo Blower

15kw 24000rpm High Speed Permanent Magnetic Synchronous Motor for Turbo Blower

Application: Industrial, Power Tools, Fans, Pumps, Compressors
Operating Speed: High Speed
Operation Mode: Electric Motor
Magnetic Structure: Permanent Magnet
Function: Driving
Structure: Rotating Pole Type (Armature Fixed)
Samples:
US$ 1000/Piece 1 Piece(Min.Order)
| Request Sample
Customization:

360° Virtual Tour

Diamond Member Since 2018

Suppliers with verified business licenses

Manufacturer/Factory & Trading Company
  • Overview
  • Product Description
  • Company Profile
  • FAQ
Overview

Basic Info.

Model NO.
SRPM112H4F15F
Number of Poles
8
Ventilation
Closed
Certification
ISO9001, CE, RoHS
Brand
Mc-Motor
Usage
Fans, Pumps, Compressors
Net Weight
19kg
Efficiency
95.5%
Cooling
Air or Water
Isolution
H/F
Ingress Protection
IP54
Installation
Ib35
Transport Package
1PC/ Carton ( Wood /Paper Box Optional)
Specification
TBD (based on real motor dimension)
Trademark
mc motor
Origin
China
HS Code
8501520000
Production Capacity
100000 Sets

Product Description

High efficiency Air / Water cooling 380V AC 15KW 24000RPM Brushless PM Electric Motor
15kw 24000rpm High Speed Permanent Magnetic Synchronous Motor for Turbo Blower
Product Description

Product Feature
1.Suitable for the 24000rpm rated speed
2.High power & High torque& High Efficiency
4.Small size
5.Low noise low vibration
6.The autonomous patented cooling structure
7.7.5-75kw serials model customization



Specifications
Model type: SRPM112H4F15F
Voltage: 380V AC
Rated Power: 10KW
Rated Torque :6N.m
Rated speed: 24000rpm
Isolation: H/F
Water/dust Proof: IP54(IP67 option)

Cooling Method: Air/ Water
Installation Method: B35


Main Service
We can provide customers with customized services, according to your motor application scenarios and needs, thus providing the best solution at a competitive price.


Customizing Range:

Power: 5KW-2MW
Speed: 2500rpm-100000rpm
Voltage: 110v-690v


Application
High-speed Compressors,Fans,Pumps
 
Company Profile

15kw 24000rpm High Speed Permanent Magnetic Synchronous Motor for Turbo Blower
15kw 24000rpm High Speed Permanent Magnetic Synchronous Motor for Turbo Blower
15kw 24000rpm High Speed Permanent Magnetic Synchronous Motor for Turbo Blower
15kw 24000rpm High Speed Permanent Magnetic Synchronous Motor for Turbo Blower
OUR MAIN PRODUCTS
15kw 24000rpm High Speed Permanent Magnetic Synchronous Motor for Turbo Blower

Other motors you will be interested in
Motor type Voltage
(V AC)
Rated power
(kW)
Rated torque (N.m) Rated speed
(rpm)
Efficiency
(%)
Service Factor Insulation Ingress protection Pole Number Weight
(kg)
Cooling Method Position Signal Installation Method
SRPM151M8XW11 380 11 11 9600 96 S1 H/F IP67 8 10 Oil circulation Resolver B35
SRPM205M8XO45 380 45 36 12000 96.3 S1 H/F IP67 8 35 Oil circulation Resolver B35
SRPM205M8XO55 380 55 43.8 12000 96.3 S1 H/F IP67 8 38 Oil circulation Resolver B35
SRPM205M8XO75 380 75 59.7 12000 96.5 S1 H/F IP67 8 43 Oil circulation Resolver B35
SRPM205M8XO90 380 90 71.6 12000 96.5 S1 H/F IP67 8 47 Oil circulation Resolver B35
SRPM205M8XO110 380 110 87.6 12000 96.5 S1 H/F IP67 8 75 Oil circulation Resolver B35
SRPM205M8XO132 380 132 105 12000 96.5 S1 H/F IP67 8 80 Oil circulation Resolver B35
SRPM205M8XO160 380 160 127.3 12000 96.5 S1 H/F IP67 8 87 Oil circulation Resolver B35
SRPM205M8XO185 380 185 147.2 12000 96.5 S1 H/F IP67 8 95 Oil circulation Resolver B35
 
FAQ

1. Can performanent magnet synchronous motors be used as generator? 
Yes. Permanent magnet synchronous motors can be used a a  generator.

2. Why three-phase AC motors cannot supply voltage to start permanent magnet synchronous motors? 
Becuase of the big innertia of the rotor and of the magnetic field the static rotor has no way to spin fast enough. 
 
3. Any special technical request on this motor's VFD driver? Do you have such driver? 
Permanent magnet synchronous motor's driver should be vector control VFD with special inner software, such as Siemens 6SE70 series, Yakawa CR5 series, ABB ACS800 series, Mitsubishi A740 series, B&R P84 and P74 series, etc.. Yes, our MH300 series VFD matches with this motor. 
 
4. Is there any protective measures to defend permanent magnet rotors from failure? 
Yes, each permanent magnet rotor passes corrossion resistance, consistency, high temperature demagnetization test, linear demagnetization test, etc. Its demagnetization index is within 2%. If the working environment is highly corrosive, kindly advise for higher protection level. 
 
5. What is this permanent magnet synchronous motor normally used for? 
This permanent magnet synchronous motor is normally used in variable frequency speed situations.

 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now

You Might Also Like

360° Virtual Tour

Diamond Member Since 2018

Suppliers with verified business licenses

Manufacturer/Factory & Trading Company
Number of Employees
51
Year of Establishment
2016-10-09