100kw 24000rpm Permanent Magnet Motor High Speed Compressor/Fan/Pump 540V DC

Product Details
Customization: Available
Application: Industrial, Power Tools, Fan, Blower, Mining, Compressor, Pump
Operating Speed: High Speed
Still deciding? Get samples of US$ 10000/Piece
Request Sample
Manufacturer/Factory & Trading Company

360° Virtual Tour

Diamond Member Since 2018

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Number of Employees
51
Year of Establishment
2016-10-09
  • 100kw 24000rpm Permanent Magnet Motor High Speed Compressor/Fan/Pump 540V DC
  • 100kw 24000rpm Permanent Magnet Motor High Speed Compressor/Fan/Pump 540V DC
  • 100kw 24000rpm Permanent Magnet Motor High Speed Compressor/Fan/Pump 540V DC
  • 100kw 24000rpm Permanent Magnet Motor High Speed Compressor/Fan/Pump 540V DC
  • 100kw 24000rpm Permanent Magnet Motor High Speed Compressor/Fan/Pump 540V DC
  • 100kw 24000rpm Permanent Magnet Motor High Speed Compressor/Fan/Pump 540V DC
Find Similar Products
  • Overview
  • Product Description
  • Company Profile
  • Our Advantages
  • Packaging & Shipping
Overview

Basic Info.

Model NO.
SRPM112H4O100
Function
Driving
Casing Protection
Protection Type
Number of Poles
4
Structure and Working Principle
Brushless
Certification
ISO9001, CE, RoHS
Brand
Mc-Motor
Rotating Speed
24000rpm
Cooling Method
Oil Cooling
Rated Power
100kw
Insolution
H/F
Installation
B35
IP Level
IP54 IP67
Efficiency
95%
Pole
4
Weight
55kgs
Transport Package
1PC/ Carton ( Wood /Paper Box Optional)
Specification
TBD (based on real motor dimension)
Trademark
mc motor
Origin
China
HS Code
8501520000
Production Capacity
100000 Sets

Product Description

100kw 20000-24000rpm Permanent Magnet Motor for High Speed Compressor/Fan/Pump Oil Cooling
100kw 24000rpm Permanent Magnet Motor High Speed Compressor/Fan/Pump 540V DC
Product Description

Product Feature
1.Suitable for the 24000rpm Rated Speed
2.Reserve a large margin of security
3.High power & High torque
4.High efficiency 
5.Small size 
6.Low noise low vibration
7.The autonomous patented cooling structure



Specifications
Voltage: 380V AC/540V DC
Rated Power: 100KW
Rated Speed:20000-24000rpm
Isolation: H
Cooling Method: Water Cooling
Ingress Protection:IP54 
Duty type: S1

Pole:4
Installation: B3,B5,B35
Max Net Weight: 70kg


Application:
high speed compressor, fan, pump
 
Company Profile

100kw 24000rpm Permanent Magnet Motor High Speed Compressor/Fan/Pump 540V DC
 
Our Advantages

100kw 24000rpm Permanent Magnet Motor High Speed Compressor/Fan/Pump 540V DC

Customer Case 

100kw 24000rpm Permanent Magnet Motor High Speed Compressor/Fan/Pump 540V DC
100kw 24000rpm Permanent Magnet Motor High Speed Compressor/Fan/Pump 540V DC100kw 24000rpm Permanent Magnet Motor High Speed Compressor/Fan/Pump 540V DC100kw 24000rpm Permanent Magnet Motor High Speed Compressor/Fan/Pump 540V DC100kw 24000rpm Permanent Magnet Motor High Speed Compressor/Fan/Pump 540V DC
Packaging & Shipping

100kw 24000rpm Permanent Magnet Motor High Speed Compressor/Fan/Pump 540V DC

Other motors you will be interested in
Motor type Voltage
(V AC)
Rated power
(kW)
Rated torque (N.m) Rated speed
(rpm)
Efficiency
(%)
Duty type  Insulation   Ingress protection Pole Number Weight
(kg)
Cooling Method position signal
SRPM160H4XO15 380 15 5.96 24000 96.5 S1 H/F IP67 4 12 Oil  Resolver
SRPM160H4XO75 380 75 35.8 20000 96.5 S1 H/F IP67 4 44 Oil  Resolver
SRPM160H4XO90 380 90 43 20000 96.5 S1 H/F IP67 4 48 Oil  Resolver
SRPM205H4XO110 380 110 52.5 20000 96.5 S1 H/F IP67 4 76 Oil  Resolver
SRPM205H4XO160 380 160 76.4 20000 96.5 S1 H/F IP67 4 86 Oil  Resolver
SRPM205H4XO200 380 200 95.5 20000 96.5 S1 H/F IP67 4 95 Oil  Resolver

FAQ
1. Can performanent magnet synchronous motor be used as generator? 

Yes. Permanent magnet synchronous motor  can work as a generator because of its special working theory. If it runs CW as a motor, then runs CCW as a generator. But please kindly note, if when you want to work it as a generator, you need to change a suitable motor controller with AFE function

 
2. Why can not directly use three phase ac supply voltage to start permanent magnet synchronous motor? 
Becuase rotor is with big innertia, and magetic files spins so fast that static rotor has no way to spin with magetic filed. 
 
3. Any special technical request on this motor's VFD driver? And Do you have such driver? 
Permanent magnet synchronous motor's driver should be vector control VFD with special inner software, such as Siemens 6SE70 series, Yakawa CR5 series, ABB ACS800 series, Mitsubishi A740 series, B&R P84 and P74 series, etc.. Yes, our MH300 series VFD matches with this motor. 
 
4. Is there any protective measures to defend permanent magnet rotor from failure? 
Yes, each permanent magnet rotor passes corrossion resistance, consistency, high temperature demagnetization test, linear demagnetization test, etc. Its demagnetization index is within 2%. But if working environment is serious oxiditive corrosion, kindly advise for higher protection level. 
 
5. Where is this permanent magnet synchronous motor normally used to? 
This permanent magnet synchronous motor is normally used to variable frequency speed situation.










 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier