for E-Truck Light Weight AC Electric 3 Phase Permanent Magnetic Motor

Product Details
Customization: Available
Application: Industrial, Power Tools, Fans, Pumps, Compressors
Operating Speed: High Speed
Manufacturer/Factory & Trading Company

360° Virtual Tour

Diamond Member Since 2018

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Number of Employees
51
Year of Establishment
2016-10-09
  • for E-Truck Light Weight AC Electric 3 Phase Permanent Magnetic Motor
  • for E-Truck Light Weight AC Electric 3 Phase Permanent Magnetic Motor
  • for E-Truck Light Weight AC Electric 3 Phase Permanent Magnetic Motor
Find Similar Products

Basic Info.

Model NO.
SRPM155L85
Operation Mode
Electric Motor
Magnetic Structure
Permanent Magnet
Function
Driving
Structure
Rotating Pole Type (Armature Fixed)
Ventilation
Closed
Certification
ISO9001, Ce, RoHS
Brand
Mc-Motor
Usage
Fans, Pumps, Compressors
Net Weight
15kg
Efficiency
96.5%
Transport Package
1PC/ Carton ( Wood /Paper Box Optional)
Specification
TBD (based on real motor dimension)
Trademark
mc motor
Origin
China
HS Code
8501520000
Production Capacity
100000 Sets

Product Description

For E-truck Light Weight AC Electric 3 Phase Permanent Magnetic Motor
for E-Truck Light Weight AC Electric 3 Phase Permanent Magnetic Motor
Product Feature

1.Suitable for the 2500rpm rated speed
2.High power & high torque
3.High efficiency
4.Small size
5.Low noise low vibration
6.Patented cooling structure
7.Easy maintenance and long life time
8.Durable, reliable


Specifications
Model type: SRPM155L85
Voltage: 380V AC
Rated Power: 5KW
Maximum Power:9KW(30s)
Rate Torque : 19N.m
Maximum Torque:34N.m
Rated Speed: 2500rpm
Maximum Speed:4000rpm
Rated Current:10A
Isolation: H
Water/Dust Proof: IP54(IP67 option)
N Weight: around 15KG
Cooling Method: natural cooling
Installation Method: MB35


Application
High-speed Compressors,Fans,Pumps

for E-Truck Light Weight AC Electric 3 Phase Permanent Magnetic Motor
for E-Truck Light Weight AC Electric 3 Phase Permanent Magnetic Motor
for E-Truck Light Weight AC Electric 3 Phase Permanent Magnetic Motor
for E-Truck Light Weight AC Electric 3 Phase Permanent Magnetic Motor

Other motors you will be interested in
Motor type Voltage
(V AC)
Rated power
(kW)
Rated torque (N.m) Rated speed
(rpm)
Efficiency
(%)
Service Factor Insulation Ingress protection Pole Number Weight
(kg)
Cooling Method Position Signal Installation Method
SRPM151M8XW11 380 11 11 9600 96 S1 H/F IP67 8 10 Oil circulation Resolver B35
SRPM205M8XO45 380 45 36 12000 96.3 S1 H/F IP67 8 35 Oil circulation Resolver B35
SRPM205M8XO55 380 55 43.8 12000 96.3 S1 H/F IP67 8 38 Oil circulation Resolver B35
SRPM205M8XO75 380 75 59.7 12000 96.5 S1 H/F IP67 8 43 Oil circulation Resolver B35
SRPM205M8XO90 380 90 71.6 12000 96.5 S1 H/F IP67 8 47 Oil circulation Resolver B35
SRPM205M8XO110 380 110 87.6 12000 96.5 S1 H/F IP67 8 75 Oil circulation Resolver B35
SRPM205M8XO132 380 132 105 12000 96.5 S1 H/F IP67 8 80 Oil circulation Resolver B35
SRPM205M8XO160 380 160 127.3 12000 96.5 S1 H/F IP67 8 87 Oil circulation Resolver B35
SRPM205M8XO185 380 185 147.2 12000 96.5 S1 H/F IP67 8 95 Oil circulation Resolver B35

FAQ
1. Can performanent magnet synchronous motor be used as generator? 

No. Permanent magnet synchronous motor is absolutely different from generator. It is only ac motor that outputs speed and torque to drive electric devices, but not power supply. 
 
2. Why can not directly use three phase ac supply voltage to start permanent magnet synchronous motor? 
Becuase rotor is with big innertia, and magetic files spins so fast that static rotor has no way to spin with magetic filed. 
 
3. Any special technical request on this motor's VFD driver? And Do you have such driver? 
Permanent magnet synchronous motor's driver should be vector control VFD with special inner software, such as Siemens 6SE70 series, Yakawa CR5 series, ABB ACS800 series, Mitsubishi A740 series, B&R P84 and P74 series, etc.. Yes, our MH300 series VFD matches with this motor. 
 
4. Is there any protective measures to defend permanent magnet rotor from failure? 
Yes, each permanent magnet rotor passes corrossion resistance, consistency, high temperature demagnetization test, linear demagnetization test, etc. Its demagnetization index is within 2%. But if working environment is serious oxiditive corrosion, kindly advise for higher protection level. 
 
5. Where is this permanent magnet synchronous motor normally used to? 
This permanent magnet synchronous motor is normally used to variable frequency speed situation.


 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier